Nanotech breath sensor detects diabetes and potentially serious complication
|
Tweet
|
|
Scientists are reporting development and successful testing of a sensor that can instantly tell whether someone has Type I diabetes. It could also be used by emergency room doctors to determine whether a patient has developed diabetic ketoacidosis, a potentially serious complication that happens when diabetics do not take enough insulin. Someday the technology may also be used by diabetics, in their own homes, to determine whether they need more insulin. A report on the sensor appears in ACS’ Analytical Chemistry, a semi-monthly journal.
Professor Sotiris E. Pratsinis and colleagues at ETH Zurich in Switzerland explain that everyone has a little bit of acetone in their breath. But people with Type I diabetes release unusually high levels of the chemical when they exhale. If they have diabetic ketoacidosis, a dangerous buildup of acetone in the blood, they exhale even-larger amounts of acetone.
Pratsinis’ team built an extremely sensitive acetone detector by directly depositing from a flame plume a thin film of semiconducting, mixed ceramic nanoparticles between a set of gold electrodes.
The device acts like an electrical resistor. When it gets hit with a puff of acetone-filled air, its resistance drops, allowing more electricity to pass between the electrodes. If a diabetic were to breathe on the sensor, its resistance would suddenly drop. When a healthy person exhales onto the nanoparticles, their resistance will not change very much. Pratsinis’ team found this new sensor can detect acetone in extremely moist air, an attribute that is critical for any breath test. It is sensitive enough to detect acetone at 20 parts per billion, a concentration that is 90 times lower than the level at which it can be found in the breath of diabetic patients.
###
ARTICLE FOR IMMEDIATE RELEASE
“Si:WO3 Sensors for Highly Selective Detection of Acetone for Easy Diagnosis of Diabetes by Breath Analysis”
DOWNLOAD FULL TEXT ARTICLE
http://pubs.acs.org/stoken/presspac/presspac/full/10.1021/ac902695n
CONTACT:
Professor Sotiris E. Pratsinis, PhD
Particle Technology Laboratory, Institute of Process Engineering
Department of Mechanical and Process Engineering
ETH Zurich
CH-8092 Zurich, Switzerland
Phone: +41 44 632 31 80
Email:
| RELATED STORIES: | ||
| Comments | [ + Post Your Own ] |
Now you're in the public comment zone. What follows is not Armenian Medical Network's stuff; it comes from other people and we don't vouch for it. A reminder: By using this Web site you agree to accept our Terms of Service. Click here to read the Rules of Engagement.
There are no comments for this entry yet. [ + Comment here + ]
We are pleased to let readers post comments about an article. Please increase the credibility of your post by including your full name and email.
All comments are reviewed by our editors before they are posted on the site. Just keep it clean, kids.