Radiation dose level affects size of lesions seen on chest CT images

Key points
- The estimated size of chest lymph nodes and lung nodules seen on CT images varies significantly when the same nodes or nodules are examined using lower versus higher doses of radiation, a new study shows.
- The study, conducted at Massachusetts General Hospital in Boston, used a 3D image processing tool to quantitatively measure the volume of the lymph nodes and lung nodules.
- "We were surprised that in both the lymph nodes and lung nodules there were cases in which the lower dose picked up lower lesion volumes as well as higher lesion volumes when compared to the higher dose scans," said Dr.
- The goal of the study was to explore the possibility of using image processing tools to better delineate lesions at low radiation doses without missing any clinical information, noted Dr.
The estimated size of chest lymph nodes and lung nodules seen on CT images varies significantly when the same nodes or nodules are examined using lower versus higher doses of radiation, a new study shows. The size of lymph nodes and lung nodules is an important determinant of treatment and treatment success.
The study, conducted at Massachusetts General Hospital in Boston, used a 3D image processing tool to quantitatively measure the volume of the lymph nodes and lung nodules. "We found that lymph node volumes were estimated at 30% lower in five cases and 10% higher in 15 cases of low dose compared to higher dose images," said Dr. Beth Vettiyil, a lead author of the study. The study found that the calculated volume of lung nodules was 46% lower in nine cases and 34% higher in 10 cases on lower dose as compared to high dose images.
"We were surprised that in both the lymph nodes and lung nodules there were cases in which the lower dose picked up lower lesion volumes as well as higher lesion volumes when compared to the higher dose scans," said Dr. Vettiyil. "We think that increased image noise (graininess of the image) on the lower dose scans may have caused the lesion volumes to vary so significantly," she said.
The goal of the study was to explore the possibility of using image processing tools to better delineate lesions at low radiation doses without missing any clinical information, noted Dr. Vettiyil. "The study indicates that radiologists can use these types of quantitative tools to supplement them in their measurements, but the use of such software measurements without the radiologist's clinical correlation might not be advisable at this stage," said Dr. Vettiyil.
The study will be presented April 17 during the ARRS Annual Meeting in Washington, DC.
###
Samantha Schmidt
sschmidt@arrs.org
703-858-4316
American Roentgen Ray Society
Written and revised by
Andrey Nailor, M.D.
Our doctors write and review articles for accuracy and keep them up to date.
health.am provides general information, not medical advice. Always consult a qualified health professional about your own health.
Explore health topics
More in this topic
Heart & Blood Vessels →
NewsEarly dose of glucose thwarts cardiac arrest: study
Patients showing heart attack symptoms who received a mixture of glucose, insulin and potassium from paramedics were half as likely to go into cardiac arrest or die than those who did not receive the dose, a study…
28 March 2012
NewsStudy finds state wealth affects women's heart disease risk
According to new research from Brigham and Women's Hospital (BWH), a state's level of wealth or poverty is linked with levels of cardiovascular inflammation in women. Cardiovascular inflammation is a key risk factor for…
21 March 2012
NewsEchocardiography offers the future for infarct size quantification
"Up until now infarct size has only been measured as part of clinical studies and not in routine clinical practice. The reason being that the reference method of gadolinium based contrast agents in MRI is expensive,…