Organic Biosensor Detects Onset of Acute Myocardial Ischemia

Key points
- Engineering researchers at the University of Arkansas have fabricated and tested a unique biosensor that measures concentrations of potassium and hydrogen ions in the human heart with high specificity.
- “AMI is triggered by insufficient blood supply to the heart muscles,” said Taeksoo Ji, assistant professor of electrical engineering.
- Working in the Organic Electronics and Devices Laboratory, Ji, research assistant professor Soyoun Jung and student Pratyush Rai developed an ion-sensitive field effect transistor, yet another type of sensor used to detect potassium and hydrogen in blood.
- Most ion-sensitive field effect transistors are silicon based.
Engineering researchers at the University of Arkansas have fabricated and tested a unique biosensor that measures concentrations of potassium and hydrogen ions in the human heart with high specificity. The research could lead to a superior method of monitoring indicators of acute myocardial ischemia, or AMI, one of the leading causes of cardiovascular failure.
“AMI is triggered by insufficient blood supply to the heart muscles,” said Taeksoo Ji, assistant professor of electrical engineering. “This lack of blood supply results in excess anaerobic metabolism, or lack of oxygen, which we know is accompanied by an increase in potassium and hydrogen ions released from cardiovascular cells. The goal is to develop a robust yet inexpensive sensor that rapidly detects these chemicals that signal the onset of AMI.”
Due in part to the National Heart Lung and Blood Institute’s emphasis on promoting research on rapid detection of the symptoms of acute myocardial ischemia, various types of biosensor designs, including ion-selective optical fibers, wave-guides, nanoparticle fluorescence sensors and ion-selective electrodes, have been used to detect potassium and hydrogen in the blood stream. Working in the Organic Electronics and Devices Laboratory, Ji, research assistant professor Soyoun Jung and student Pratyush Rai developed an ion-sensitive field effect transistor, yet another type of sensor used to detect potassium and hydrogen in blood.
Most ion-sensitive field effect transistors are silicon based. Instead of silicon, Ji’s team worked with a low-cost organic semiconductor known as poly 3-hexylthiophene, which they fabricated on a flexible substrate. The design and fabrication process was based on special devices used to deposit organic semiconductors on substrates. Organic semiconductor films do not require high vacuum and temperature cycles for deposition and curing, which reduces cost of production.
The researchers also developed a smoothing technique to assess the effect of external electric fields on the devices. The human heart creates a great amount of electrical charge from the organ’s network of neurons that help it relay electrical impulse for pace-making activity. The myocardium, or the middle section of the heart wall, has intense electrical activity. Diagnostic tools such as electrocardiograms detect electric fields emanating from the heart. To operate properly, implantable biosensor devices must be immune to these electric fields, or background noise.
The researchers’ smoothing technique and noise calculation demonstrated a high signal-to-noise ratio. Overall, the testing and validation process for the device displayed stable calibration characteristics, which proved its independence from surrounding electrical fields. In other words, the sensor was immune to external voltages.
Ji collaborates with Vijay Varadan, distinguished professor of electrical engineering and director of the Center for Wireless Nano-, Bio- and Info-Tech Sensors and Systems, which is supported by the National Science Foundation. Led by Ji, the Organic Electronics and Devices Laboratory is one of the center’s four laboratories.
Written and revised by
David Cohen, M.D.
Our doctors write and review articles for accuracy and keep them up to date.
health.am provides general information, not medical advice. Always consult a qualified health professional about your own health.
Explore health topics
More in this topic
Heart & Blood Vessels →
GuideAcute Rheumatic fever & Rheumatic Heart Disease
Introduction Essentials of Diagnosis Uncommon in the United States but may be overlooked. Peak incidence ages 5-15 years. Diagnosis based on Jones criteria and confirmation of streptococcal infection. May involve mitral…
21 December 2005
GuideAcute Heart Failure & Pulmonary Edema
Introduction Essentials of Diagnosis Acute onset or worsening of dyspnea at rest. Tachycardia, diaphoresis, cyanosis. Pulmonary rales, rhonchi; expiratory wheezing. X-ray shows interstitial and alveolar edema with or…
21 December 2005
GuideAcute coronary syndromes
Introduction Acute coronary syndromes comprise the spectrum of unstable cardiac ischemia from unstable angina to acute myocardial infarction. Rather than the traditional nomenclature of unstable angina, non-Q wave and Q…
20 December 2005