Other Screening Tests

Key points
- The search for alternative methods of screening for breast cancer is stimulated by a desire to increase accuracy and to overcome some of the technical barriers associated with film screen mammography.
- Smith: Cancer Screening, Department of Cancer Control, American Cancer Society, Atlanta, Georgia C.
- All current routine screening of the breast is performed with dedicated equipment, due to the requirement of high spatial resolution and contrast for mammography.
- There are major benefits and significant barriers to digital mammography use for routine screening.
The search for alternative methods of screening for breast cancer is stimulated by a desire to increase accuracy and to overcome some of the technical barriers associated with film screen mammography. We do not address adjunctive modalities but discuss only those with a possible use as a breast cancer screening tool. Many screening methods have and are being suggested, including electrical impedance, light scanning, and infrared imaging of the breast. There has been no substantiation of a benefit accruing from these technologies for detection of early breast cancer in a screening situation. However, digital full-field mammography and magnetic resonance (MR) mammography seem to hold promise in this regard.
All current routine screening of the breast is performed with dedicated equipment, due to the requirement of high spatial resolution and contrast for mammography. Digital techniques promise to fulfill these requirements. There are two general techniques of performing digital mammography. The first and less desirable method is digitizing a film screen mammogram. Although this allows for some of the desirable features of digital mammography, it also preserves some undesirable attributes of the film screen technique. The second method replaces the film screen cassette combination with a specialized detector capable of transforming the latent x-ray image into an electronic digital image.
There are major benefits and significant barriers to digital mammography use for routine screening. Because there is no film processing involved, image acquisition is much faster, producing a mammogram in approximately 6 seconds as compared to the 90 to120 seconds required for film development.
In a situation in which 40 or more screening examinations are done per day, this higher performance could increase throughput. Once a digital image is acquired, it can be manipulated to adjust contrast and brightness to the individual patient. Regions of interest may also be magnified. This can all be accomplished with the single x-ray exposure used to produce the original image and may be particularly useful in the dense breast, in which a masking effect for early cancer detection can exist.
Issues of concern associated with screening mammography are the variability of interpretation and the false-positive rate involved with screening. With the evolution of digital screening mammography, computer video diagnosis and computer-aided detection (CAD) is becoming a reality. Using detection algorithms for specific mammographic features associated with malignancy, this software is able to indicate these findings on the digital image. However, this benefit is balanced by the indication of densities that may be fictitious or due to overlapping structures within the breast. Thus, if there were too many false-positives, CAD would lose its use.
However, if these false-positives could be kept to a minimum, perhaps one to two per image, and detect a high degree of true findings, perhaps 85% to 90%, then real benefit could be realized. Recent presentations indicate that these factors are real. CAD could then function as a second reader and possibly have a positive impact on variability and false-positive diagnoses while not diminishing the high sensitivity of screening mammography. Underserved areas, especially rural settings and remote facilities that provide mammographic services, could benefit from the ability to transport digital images almost anywhere. This can be done without loss of image fidelity and rapidly enough to be of clinical use. Preliminary results from a screening trial comparing routine film screen images with digital images on the same patient suggest at least equivalence in detection of breast cancer and a significantly lower recall and false-positive rate for digital screening mammography.
Written and revised by
Gerald Hurowitz, M.D.
Our doctors write and review articles for accuracy and keep them up to date.
health.am provides general information, not medical advice. Always consult a qualified health professional about your own health.
Explore health topics
More in this topic
Cancer →
NewsCoupling head and neck cancer screening and lung cancer scans could improve survival
Adding head and neck cancer screenings to recommended lung cancer screenings would likely improve early detection and survival, according to a multidisciplinary team led by scientists affiliated with the University of…
13 January 2015
NewsNew insights into breast cancer spread could yield better tests and treatments
A study combining tumor cells from patients with breast cancer with a laboratory model of blood vessel lining provides the most compelling evidence so far that a specific trio of cells is required for the spread of…
27 November 2014
NewsNew Study Identifies Opportunities To Reduce Patient Burden Associated With Breast Cancer Screening
New technology and better screening strategies can lower the rate of false-positive results, which impose a substantial financial and psychological burden on women. The many misperceptions about breast cancer screening…