FDA sees rare but serious issue with stents

Key points
- Health regulators are investigating a rare but potentially serious problem with a newer class of heart stents that causes the tiny tubular devices made of wire mesh to shrink, or lengthen, after implantation.
- Gregg Stone, a cardiologist at New York Presbyterian/Columbia Hospital who has led many clinical trials for all of the major stent makers, said the stent deformation seems to occur most often in complex cases of blocked blood vessels.
- The problem appears to occur most frequently in the Promus and Ion devices made by Boston Scientific Corp, the Food and Drug Administration said.
- The agency said it still views the Ion stent, which it approved for use in the spring, as safe when used for its authorized indications.
Health regulators are investigating a rare but potentially serious problem with a newer class of heart stents that causes the tiny tubular devices made of wire mesh to shrink, or lengthen, after implantation.
The problem appears to occur most frequently in the Promus and Ion devices made by Boston Scientific Corp, the Food and Drug Administration said. Promus Element is sold outside the U.S. The company submitted a pre-market application with the FDA earlier this year.
The agency said it still views the Ion stent, which it approved for use in the spring, as safe when used for its authorized indications.
"FDA is actively working with (drug-eluting stent) manufacturers, including Boston Scientific, to better understand longitudinal stent deformation with respect to its causes, predisposing underlying anatomic conditions, operator techniques that can reduce the likelihood of its occurrence, and treatment strategies should it occur," the agency said in an emailed response to a Reuters inquiry.
Boston Scientific, the biggest manufacturer of stents with more than a third of the $4 billion global market, declined to comment on discussions with the FDA. Boston Scientific had a 36 percent share of the global market and a 49 percent share of the U.S. market at the end of the third quarter.
The company's business has struggled on several fronts in recent years, including a series of stent recalls that date to 2004 and a heavy debt load from its ill-fated acquisition of stent and pacemaker manufacturer Guidant Corp in 2006.
Concerns about stent deformation were raised in two smaller cardiology journals published in the U.S. and Europe, and the issue was the subject of a discussion at the Transcatheter Cardiovascular Therapeutics meeting in San Francisco earlier this month.
Drug-eluting stents prop open diseased arteries and deliver medicine to keep the vessel from reclogging. In the case of longitudinal deformation, the stents become deformed inside the vessel, creating a clotting risk that could lead to a heart attack.
Some factors that appear to predispose a patient to the problem include calcification of coronary arteries, implantation in a twisted blood vessel and improper positioning of the stent, the FDA said.
The FDA said that only one instance of longitudinal stent deformation was reported from trials of more than 4,600 patients treated with a Promus stent. But it said it was also aware of recently published case reports on the problem and that an unspecified number of significant adverse events had been reported to the agency.
"At this time, additional data collection and analyses are ongoing, but the information available to date indicates that the Ion Paclitaxel-Eluting Platinum Chromium Stent remains safe and effective when used for its approved indications," the agency said.
Written and revised by
David Cohen, M.D.
Our doctors write and review articles for accuracy and keep them up to date.
health.am provides general information, not medical advice. Always consult a qualified health professional about your own health.
Explore health topics
More in this topic
Heart & Blood Vessels →
NewsDrug-eluting stents are preferred therapy for revascularization of chronic total occlusions
A systematic review of medical evidence has determined drug-eluting stents (DES) outperform bare metal stents (BMS) for revascularization of chronic total occlusions. Researchers found coated stents reduce restenosis…
10 February 2011
NewsRare mutations linked with catastrophic aortic aneurysms
TAAD causes thousands of deaths in the United States each year. Although timely surgical repair of aneurysms can prevent death, thoracic aneurysms are often asymptomatic until dissection (tearing of the vessel wall),…
19 November 2010
NewsBypass, stents equally safe five years on: study
Patients who got heart bypass surgery and those who got their blocked arteries propped open with stents fared equally well five years after their procedures, South Korean doctors reported on Wednesday. The study of more…