Many Patients with Implantable Cardioverter-Defibrillators Do Not Meet Criteria for Use

Key points
- Several randomized controlled trials have shown the effectiveness of ICDs for preventing sudden cardiac death in patients with advanced systolic heart failure.
- Al-Khatib, M.D., M.H.S., of the Duke Clinical Research Institute, Durham, N.C., and colleagues conducted a study to determine the number, characteristics, and in-hospital outcomes of patients who received a non-evidence-based ICD.
- The researchers found that of 111,707 initial primary prevention ICD implants that occurred during the study period, 25,145 were for a non-evidence-based indication (22.5 percent).
- "Although the absolute difference in complications between the 2 groups is modest, these complications could have significant effects on patients' quality of life and health care use, including length of hospital stay and costs.
A study that included more than 100,000 patients who received implantable cardioverter-defibrillators (ICDs) found that about 20 percent did not meet evidence-based guidelines for receipt of an ICD, and that these patients had a significantly higher risk of in-hospital death than individuals who met criteria for receiving an ICD, according to a study in the January 5 issue of JAMA.
Several randomized controlled trials have shown the effectiveness of ICDs for preventing sudden cardiac death in patients with advanced systolic heart failure. But practice guidelines do not recommend use of an ICD for primary prevention in patients recovering from a heart attack or coronary artery bypass graft surgery and those with severe heart failure symptoms or a recent diagnosis of heart failure. "The degree to which physicians in routine clinical practice follow these evidence-based recommendations is not clear," the authors write.
Sana M. Al-Khatib, M.D., M.H.S., of the Duke Clinical Research Institute, Durham, N.C., and colleagues conducted a study to determine the number, characteristics, and in-hospital outcomes of patients who received a non-evidence-based ICD. The study included an analysis of cases submitted to the National Cardiovascular Data Registry-ICD Registry between January 2006 and June 2009.
The researchers found that of 111,707 initial primary prevention ICD implants that occurred during the study period, 25,145 were for a non-evidence-based indication (22.5 percent). Of these, 9,257 were in patients within 40 days of a heart attack (36.8 percent) and 15,604 were in patients with newly diagnosed heart failure (62.1 percent). The risk of in-hospital death was significantly higher in patients who received a non-evidence-based device than in patients who received an evidence-based device (0.57 percent vs. 0.18 percent). The risk of any postprocedure complication was significantly higher in the non-evidence-based ICD group at 3.23 percent compared with 2.41 percent in the evidence-based group.
"Although the absolute difference in complications between the 2 groups is modest, these complications could have significant effects on patients' quality of life and health care use, including length of hospital stay and costs. Importantly, these complications resulted from procedures that were not clearly indicated in the first place. While a small risk of complications is acceptable when a procedure has been shown to improve outcomes, no risk is acceptable if a procedure has no demonstrated benefit," the authors write.
Any adverse event and death were significantly higher in patients who received a non-evidence-based device. The median (midpoint) length of hospital stay was significantly longer for patients who received a non-evidence-based ICD compared with patients who received an evidence-based ICD (3 days vs. 1 day). Also, there was substantial variation in non-evidence-based ICDs by site.
The proportion of ICD implants performed by the different types of physician specialty was 66.6 percent for electrophysiologists, 24.8 percent for nonelectrophysiologist cardiologists, 2.6 percent for thoracic surgeons, and 6.1 percent for other specialists. The rate of non-evidence-based ICD implants was significantly lower for electrophysiologists (20.8 percent) than nonelectrophysiologists (24.8 percent for nonelectrophysiologist cardiologists; 36.1 percent for thoracic surgeons; and 24.9 percent for other specialties). There was no clear decrease in the rate of non-evidence-based ICDs over time.
Written and revised by
Andrey Nailor, M.D.
Our doctors write and review articles for accuracy and keep them up to date.
health.am provides general information, not medical advice. Always consult a qualified health professional about your own health.
Explore health topics
More in this topic
Heart & Blood Vessels →
NewsStatin guidelines miss middle-age patients and over-target seniors
The newest guidelines for the use of cholesterol-lowering statins in people at risk of heart disease may be too generic, excluding middle-aged adults who could benefit from the drugs, and over-prescribing in older…
13 March 2015
NewsParticipants of cardiac clinic trials do not represent real world patients, study finds
A new analysis of clinical trial participation in the largest ongoing observational study of U.S. heart attack patients has found participants are not representative of the larger patient base, according to a study led…
28 August 2014
NewsHeart attack patients could be treated more quickly after Manchester research
Clinical judgement, combined with an electrocardiogram (ECG) and blood test on arrival, is effective in reducing unnecessary hospital admissions for chest pain, a new study shows. The findings of a research group in…